TECHNICAL SPECIFICATIONS
Model
E001GER31
Phase
Single phase with ground
Capacity
1000 VA / 1000 W
INPUT
Nominal Voltage
100/110/115/120 /127 VAC or 200/208/220/230/240 VAC
Voltage Range
55-150 VAC ± 5% or 110-300 VAC ± 5% @ 50% Load, 80-150 VAC ± 5% or 160-300 VAC ± 5% @ 100% Load
Frequency Range
40Hz ~ 70Hz
Harmonic Distortion(THDi)
≦5% @ Nominal Input Voltage
Power Factor
≧ 0.99 @ Nominal Voltage (100% load)
OUTPUT
Output Voltage
100*/110*/115*/120/127 VAC or 200*/208*/220/230/240 VAC
AC Voltage Regulation (Batt.
Mode)
± 1%
Frequency Range (Synchronized Range)
57 ~ 63 Hz or 47 ~ 53 Hz
Frequency Range
(Batt. Mode)
60Hz ± 0.1Hz or 50 Hz ± 0.1Hz
Current Crest Ratio
3:1 (max.)
Harmonic Distortion
≦ 2 % THD (Linear Load); ≦ 4 % THD (Non-Linear Load)
Transfer Time – AC Mode to Battery Mode
Zero
Transfer Time – Inverter to Bypass
4 ms (Typical)
Waveform (Batt. Mode)
Pure Sinewave
EFFICIENCY
AC Mode
≧89% @ Full Charged Battery
ECO Mode
≧ 96% @ Full Charged Battery
Battery Mode
≧88%
BATTERY
Battery Type
12 V / 9 AH – 12 V / 7 AH
Numbers
2 – 3
Typical Recharge Time
3 Hours Recover to 95% Capacity for Internal Battery@ 2A Charging Current
Charging Current
100/110/115/120 /127 VAC Models: Default 2A, Max. 8A Adjustable
200/208/220/230/240 VAC Models: Default 2A, Max. 12A Adjustable
Charging Voltage
27.4 VDC ± 1% – 41.1 VDC ± 1%
PHYSICAL
Dimension, D X W X H (mm)
410 x 438 x 88
Net Weight (without battery) (kgs)
6.6 – 7.8
Net Weight (with battery) (kgs)
11.6 – 14.1
ENVIRONMENT
Humidity
20-90 % RH @ 0- 40°C (Non-Condensing)
Noise Level
Less than 50dBA @ 1 Meter
Altitude
10% de-rating for over 1000m (The altitude should not exceed 3000m)
MANAGEMENT
Smart RS-232 / USB
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC
Optional SNMP
Power management from SNMP manager and web browser
Product Variants
ExTell Galaxy, Rack Tower Single Phase External Battery 1 KVA Online UPS, PF = 1.0
ExTell Galaxy, Rack Tower Single Phase External Battery 1.5 KVA Online UPS, PF = 1.0
ExTell Galaxy, Rack Tower Single Phase External Battery 2 KVA Online UPS, PF = 1.0
ExTell Galaxy, Rack Tower Single Phase External Battery 3 KVA Online UPS, PF = 1.0
ExTell Galaxy, Rack Tower Single Phase External Battery 6 KVA Online UPS, PF = 1.0
ExTell Galaxy, Rack Tower Single Phase External Battery 10 KVA Online UPS, PF = 1.0
Downloads
FAQ’S
Lorem Ipsum is simply dummy text of the printing and typesetting industry. Lorem Ipsum has been the industry’s standard dummy text ever since the 1500s, when an unknown printer took a galley of type and scrambled it to make a type specimen book. It has survived not only five centuries, but also the leap into electronic typesetting, remaining essentially unchanged.