Product ID E001GIT31

ExTell Galaxy, Tower Single Phase Internal Battery 1 KVA Online UPS, PF = 1.0

ExTell Galaxy Single Phase Online UPS is the ideal protection and power backup device for your sensitive and critical loads. With a true Double-Conversion online design, Galaxy gives you a pure sinewave output with a Unity Power Factor Load Carrying capacity.

It has a rich LCD Display that provides you all the vital information and has configurable Voltage and Charging current adjustment capability. Backed up with ECO Mode for Energy Saving, Galaxy is a SMART UPS that is Network Manageable by the addition of an external SNMP Card. With an optimized and low THDi and Emergency Power Off Function, Galaxy guarantees full time protection and zero switching time.

Power Factor 0.81.0
Battery Backup InternalExternal
Mounting Type TowerRack Tower

Description

Product Overview

Product Variants

Downloads

FAQ’S

Features

  • Unity Power Factor

  • True Double Conversion

  • EPO Function

  • Network Manageable

  • ECO Mode for Energy Saving

  • Low THDi to reduce power system pollution

  • Adjustible charging current

TECHNICAL SPECIFICATIONS

Model

E001GIT31

Capacity

1000 VA / 1000 W

INPUT

Nominal Voltage

100/110/115/120 /127 VAC or 200/208/220/230/240 VAC

Voltage Range

55-150 VAC ± 5% or 110-300 VAC ± 5% @ 50% Load, 80-150 VAC ± 5% or 160-300 VAC ± 5% @ 100% Load

Frequency Range

40Hz ~ 70Hz

Harmonic Distortion(THDi)

≦5% @ Nominal Input Voltage

Power Factor

≧ 0.99 @ Nominal Voltage (100% Load)

OUTPUT

Output Voltage

100*/110*/115*/120/127 VAC or 200*/208*/220/230/240 VAC

AC Voltage Regulation (Batt. Mode)

± 1%

Frequency Range (Synchronized Range)

57 ~ 63 Hz or 47 ~ 53 Hz

Frequency Range
(Batt. Mode)

60Hz ± 0.1Hz or 50 Hz ± 0.1Hz

Current Crest Ratio

3:1 (max.)

Harmonic Distortion

≦ 2 % THD (Linear Load); ≦ 4 % THD (Non-Linear Load)

Transfer Time
AC Mode to Battery Mode
Inverter to Bypass
Zero
4 ms (Typical)

Waveform (Batt. Mode)

Pure Sinewave

EFFICIENCY

AC Mode

≧89% @ Full Charged Battery

ECO Mode

≧ 96% @ Full Charged Battery

Battery Mode

≧88%

BATTERY

Battery Type

12 V / 9 AH – 12 V / 7 AH

Numbers

2 – 3

Typical Recharge Time

3 Hours Recover to 95% Capacity for Internal Battery@ 2A Charging Current

Charging Current

100/110/115/120 /127 VAC Models: Default 2A, Max. 8A Adjustable
200/208/220/230/240 VAC Models: Default 2A, Max. 12A Adjustable

Charging Voltage

27.4 VDC ± 1% – 41.1 VDC ± 1%

PHYSICAL

Dimension, D X W X H (mm)

410 x 438 x 88

Net Weight (without battery) (kgs)

6.6 – 7.8

Net Weight (with battery) (kgs)

11.6 – 14.1

ENVIRONMENT

Humidity

20-90 % RH @ 0- 40°C (Non-Condensing)

Noise Level

Less than 50dBA @ 1 Meter

Altitude

10% de-rating for over 1000m (The altitude should not exceed 3000m)

MANAGEMENT

Smart RS-232/USB

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC

Optional SNMP

Power management from SNMP manager and web browser

Product Variants

ExTell Galaxy, Tower Single Phase Internal Battery 1 KVA Online UPS, PF = 1.0

ExTell Galaxy, Tower Single Phase Internal Battery 1.5 KVA Online UPS, PF = 1.0

ExTell Galaxy, Tower Single Phase Internal Battery 2 KVA Online UPS, PF = 1.0

ExTell Galaxy, Tower Single Phase Internal Battery 3 KVA Online UPS, PF = 1.0

ExTell Galaxy, Tower Single Phase Internal Battery 6 KVA Online UPS, PF = 1.0

ExTell Galaxy, Tower Single Phase Internal Battery 10 KVA Online UPS, PF = 1.0

Downloads

FAQ’S

Lorem Ipsum is simply dummy text of the printing and typesetting industry. Lorem Ipsum has been the industry’s standard dummy text ever since the 1500s, when an unknown printer took a galley of type and scrambled it to make a type specimen book. It has survived not only five centuries, but also the leap into electronic typesetting, remaining essentially unchanged.